Direct Reading, 127 mm Scale, ±10% FS Accuracy, Interchangeable Flowtubes

SPECIFICATIONS
Service: Compatible gases and liquids.
Wetted Materials:
Flowtube: Borosilicate glass.
Float: 316 stainless steel.
Float Stops: PTFE.
End Fittings: Brass or 316 stainless steel.
O-rings: Buna-N on brass models and Fluoroelastomer on stainless steel models.
Temperature Limits: 250°F (121°C).
Pressure Limits: 200 psig (13.8 bar).
Accuracy: ±10% FS @ 70°F (21.1°C) and 14.7 psia (1 atm absolute).
Repeatability: ±0.25% of scale reading.
Scale: Direct reading 127 mm scales for air or water.
Turn-down Ratio: 10:1.
Connection: 3/8" female NPT.
Mounting: Vertical.
Valve: 6-turn needle (standard on models with valve).