SPECIFICATIONS
Inputs: (Field Selectable) Analog: 4-20 mA, 0-20 mA, 0-5 V, 1-5
V, 0-10 V, 1-10V.
Display: 6 digit, 7 segment 0.56˝ (14.2 mm) high;
Rate: -19,999(0) to 29,999(0) with selectable extra zero;
Total: 0 to 999,999; automatic lead zero blanking.
Accuracy: ±0.1% F.S., ±0.004 mA.
Supply Voltage: 115 or 230 VAC ±10%, 50/60 Hz.
Power Consumption: 12 VA.
Enclosure: 1/8 DIN, high impact plastic.
Operating Temperature: 32 to 140ºF (0 to 60ºC).
Alarm Points: 0 or 2.
Alarm Output Relay Ratings: 2 SPDT (form C), rated 2 A @ 30
VDC or 2 A @ 250 VAC resistive, 1/14 hp @ 125/250 VAC for
inductive.
Alarm Point Deadband: 0 to 100% of full scale, user selectable.
Isolation: 500 VDC or peak AC, input-to-output or input/output-to-power line.
Loop Power Supply: Isolated 24 VDC ±5% @ 20 mA, regulated.
Maximum loop resistance is 1200Ω.
Weight: 16 oz (454 g).
Front Panel Rating: NEMA 4X, Panel gasket provided. |