SPECIFICATIONS
Service: Water.
Wetted Materials:

Model

Body

Flange
Nut

Float
Stop

Float

O'ring

Female
Thread

Male
Thread

90° Male
NPT Elbow

Metric
Union

LFMA

Polycarbonate

ABS

ABS

316 SS

Fluoroelastomer

/

ABS

PVC

ABS

LFMB

Polycarbonate

ABS

ABS

316 SS

Fluoroelastomer

/

ABS

PVC

ABS

LFMC

Polycarbonate

ABS

ABS

316 SS

Fluoroelastomer

/

ABS

PVC

ABS

LFMD

Polycarbonate

ABS

Polypropylene

316 SS

Fluoroelastomer

PA66
(nylon)

PA66
(nylon)

PVC

PVC

LFME

Polycarbonate

ABS

Polypropylene

316 SS

Fluoroelastomer

PA66
(nylon)

PA66
(nylon)

PVC

PVC

LFMF

Polycarbonate

ABS

Polypropylene

316 SS

Fluoroelastomer

PA66
(nylon)

PA66
(nylon)

/

ABS

Pressure Limit: 120 psi (8.2 bar) at 68°F (20°C); 90° elbow fittings: 116 psi (8 bar) at 68°F (20°C).
Accuracy:
±5%.
Process Connection:
LFMA: 1/2" male NPT (optional 20 mm metric union).
LFMB: 1/2" male NPT (optional 20 mm metric union or 1/2" male NPT with 90° elbow).
LFMC: 1/2" male NPT (optional 20 mm metric union, 3/4" male NPT, or 1/2" male NPT with 90° elbow).
LFMD: 3/4" male NPT (optional 32 mm metric union, 3/4" female NPT, or 3/4" male NPT with 90° elbow).
LFME: 1" male NPT (optional 40 mm metric union, 1" female NPT, or 1" male NPT with 90° elbow).
LFMF: 2" male NPT (optional 63 mm metric union or 2" female NPT).
Weight: LFMA: 2 oz (56.7 g); LFMB: 3 oz (85.0 g); LFMC: 4 oz (113.4 g); LFMD: 10 oz (283.5 g); LFME: 15 oz (425.2 g); LFMF: 40 oz (1.1 kg).

CAUTION: Series LFM Flowmeters are for indoor use only or areas without direct sunlight. Polycarbonate is adversely affected by ultraviolet light.