Portable Ultrasonic Flowmeter Converter
Compact and Lightweight

SPECIFICATIONS
Service: Homogeneous liquids (water, sea water, oil, and fluid of unknown velocity) capable of ultrasonic wave propagation.
Input: BNC connector, coaxial cable from sensor.
Range: 0 to ±105 fps (0 to ± 32 m/s).
Display: LCD, 240 x 320 dot (with back light).
Accuracy: ±1.0% of rate.
Power Requirement: Built in special type Ni-Cad battery (continuous operation time: 5 hours without printer and back light off) (recharging time: 3 hours, power adapter used).
Power Consumption: 12 W or less.
Power Adapter: Special type power adapter 90 to 264 VAC, 47/63Hz.
Power Failure Backup: Memory backup with lithium battery (effective term, 5 years).
Temperature Limits: Ambient 131°F (55°C) without printer; 113°F (45°C) with printer.
Output: 4 to 20 mA DC, 1 point (load resistance, 0 to 1 kohms).
Serial Communications: RS-232C (not isolated), 1 point.
Enclosure Rating: Dust-proof, IP50.
Materials: Plastic case.
Weight: 3.3 lb (1.5 kg) without printer; 4.4 lb (2.0 kg) with printer.