Series
RSF

Rotatable Scale Flowmeter
Dual, Rotatable Direct Reading Scales for Air and Water, ±7% Accuracy

   

SPECIFICATIONS
Service: Compatible gases or liquids.
Wetted Materials:
Flowtube: Borosilicate glass.
Float: Brass/SS models: 316 SS; PTFE models: PTFE.
Tube Shield: Polycarbonate.
Float Stops: Brass/SS models: 316 SS; PTFE models: PTFE.
End Fittings: Brass/SS models: Brass or 316 SS; PTFE models: PTFE.
O-rings: Brass/SS models: Fluoroelastomer; PTFE models: PTFE.
Temperature Limits: 250°F (121°C). PTFE models: 150°F (65°C).
Pressure Limits: 150 psig (10.34 bar) @ 200°F (93°C). PTFE models: 100 psig (6.7 bar).
Accuracy: ±7% FS.
Repeatability: ±0.25% FS.
Scale: Direct Reading 127 mm scales for air and water.
Turn-Down Ratio: 10:1.
Connections: Two 3/8" female NPT.
Mounting: Vertical or panel mount.
Panel Cutout: Drill two 7/8" diameter holes 9.0" (229 mm) apart (for panel mount meters only).
Valve: 6-turn needle (standard on models indicating "with valve").
Agency Approvals: CE.