SPECIFICATIONS
Service: Liquid flow through which ultrasonic signal can be transmitted
(water, sea water, oil, and fluid of unknown velocity).
Turbidity: 10000 deg (mg/L) or less.
Type of Flow: Well-developed turbulent or laminar flow in a full-filled pipe.
Range: 0 to ±32 m/s (bidirectional flow).
Flow Pipe Sizes: SX1-A: 1.97 to 15.75 in (50 to 400 mm), SX1-B: 1.97 to
47.24 in (50 to 1200 mm), SX1-C: 7.87 to 236.2 in (200 to 6000 mm).
Accuracy: Pipe Size: 0.51 in (13 mm) to under 1.99 in (50 mm) ±0.03 m/s for flow rate: under 2 m/s, ±0.75% to ±1.5% of rate for flow rate:
2 m/s to 32 m/s;
Pipe Size: 1.99 in (50 mm) to under 11.8 in (300 mm) ±0.02 m/s for flow rate: under 2 m/s, ±0.5% to ±1.0% of rate for flow rate:
1 m/s to 32 m/s;
Pipe Size: 11.8 in (300 mm) up to 19.69 ft (6000 mm) ±0.01 m/s for flow rate: under 1 m/s, ±0.5% to ±1.0% of rate for flow rate
1 m/s to 32 m/s.
Response Time: 0.5s or less.
Temperature Limits: Ambient 176°F (80°C). Fluid Temperature: -40 to 176°F
(-40 to 80°C) for SX1-A, SX1-B, SX1-C.
Enclosure Rating: IP67.
Materials: SX1A: Plastic case and 304 Stainless Steel and plastic guide rail;
SX1B and SX1C: Plastic case; Silicone rubber couplers on all models.
Sensor Cable: Radio frequency coaxial cable (RG-58A/U), see accessories
table for specific lengths.
Electrical Connection: Screw terminals.
Mounting: Clamped on pipe wall.