SPECIFICATIONS
Service: Liquid flow through which ultrasonic signal can be transmitted
(water, sea water, oil, and fluid of unknown velocity).
Turbidity: 10000 deg (mg/L) or less.
Type of Flow: Well-developed turbulent or laminar flow in a full-filled pipe.
Range: 0 to 105 fps (0 to ±32 m/s) (bidirectional flow).
Flow Pipe Sizes: SX2-A: 0.51 to 3.94 in (13 to 100 mm), SX2-B: 1.97 to
15.75 in (50 to 400 mm).
Accuracy: Pipe Size: 0.51 in (13 mm) to under 1.99 in (50 mm) ±0.03 m/s for flow rate: under 2 m/s, ±0.75% to ±1.5% of rate for flow rate: 2 m/s to 32 m/s;
Pipe Size: 1.99 in (50 mm) to under 11.8 in (300 mm) ±0.02 m/s for flow rate: under 2 m/s, ±0.5% to ±1.0% of rate for flow rate: 1 m/s to 32 m/s;
Pipe Size: 11.8 in (300 mm) up to 19.69 ft (6000 mm) ±0.01 m/s for flow rate: under 1 m/s, ±0.5% to ±1.0% of rate for flow rate: 1 m/s to 32 m/s.
Response Time: 0.5s or less.
Temperature Limits: Ambient 176°F (80°C). Fluid Temperature: -40 to
212°F (-40 to 100°C) for SX2-A, -40 to 392°F (-40 to 200°C) for SX2-B.
Enclosure Rating: NEMA 3 (IP52).
Materials: SX2-A: Plastic case, aluminum and plastic guide rail, silicone
rubber coupler; SX2-B: 304SS case, aluminum and 304SS guide rail, silicone
grease coupler.
Sensor Cable: Radio frequency coaxial cable (RG-58A/U), 16.4 ft (5 m).
Electrical Connection: Screw terminals.
Mounting: Clamped on pipe wall.
Weight: SX2-A: 1.32 lb (0.6 kg), SX2-B: 3.53 lb (1.6 kg).
|