SPECIFICATIONS
Relay Output: TDC1: 1 SPDT Form C, TDC2: 2 SPDT Form C (one
latching relay).
Relay Load: 240 VAC, 12 A resistive, 1/2 hp.
Switching Mode: Field selectable NO or NC.
Supply Voltage: 120/240 VAC, 50/60 Hz., selectable.
Current Consumption: .25 amps maximum.
Time Delay: Adjustable, 0.15 to 60 seconds.
Sensor Voltage Supply: 13.5 VDC, 100 mA max., nominal.
Sensor Trigger Point: Dry <12mA, wet >12 mA.
Sensor Input: Terminal block.
Mounting: EN 50 022 standard 32 mm DIN or panel mount.
Enclosure: Polypropylene, flame retardant.
Temperature Limits: -4 to 158°F (-20 to 70°C).
Agency Approvals: CE, CSA.
|