SPECIFICATIONS
Service: Clean gases or clean low viscosity liquids (≤10
centistokes) depending on model.
Wetted Materials: 40% glass filled PPS (polyphenylene sulfide)
sensor and fittings, sapphire bearing, Viton® O-ring.
Accuracy: ±3% full scale.
Linearity: ±3% full scale.
Repeatability: ±0.2% full scale (liquid models), ±1%
full scale (gas models).
Temperature Limits: 122°F (50°C). Temperature Sensitivity: ±0.2%
per °C.
Pressure Limits: 100 psi (6.89 bar) at 20°C (liquid models); 40
psi at 20°C (gas models). Pressure Sensitivity: ±0.07% per mm
Hg (for air at 1 to 3 atm).
Supply Voltage: 12.5 ±2 VDC, 30 mA (connecting cable or cable/adapter
sold separately).
Output: 0 to 5 VDC (gas models), 0 to 5 VDC and 7.5 VDC peak pulse
output, 0 to 400 pps typical (liquid models).
Weight: 1 lb (0.5 kg).
Agency Approvals: CE.
|