SPECIFICATIONS
Service: Air, nitrogen, or non-corrosive, non-combustible
gases.
Wetted Materials: 304 SS probe, glass coated sensor, epoxy.
Accuracy: ±1% FS, ±0.5% of reading over 32 to
122°F (0 to 50°C) and 5 to 30 psia (0.35 to 2 kg/cm²).
Repeatability: 0.2% F.S.
Temperature Limits: -40 to 250°F (-40 to 121°C).
Pressure Limits: 150 psig (10 kg/cm² G) max.
Power Requirements: 15 to 18 VDC, 300 mA max.
Output: 4 to 20 mA, linear.
Response Time: 0.2 seconds to 63% of final velocity value.
Loop Resistance: 400 Ω max.
Electrical Connection: Four wire standard connector.
Probe Dimensions: 1/4" (6.35 mm) OD, 13" (33 cm) length.
Operating Temperature: 32 to 122°F ( 0 to 50°C).
Weight: 0.7 lb (0.30 kg). |