SPECIFICATIONS
Service: Compatible liquids.
Wetted Materials: 316 SS, 316L SS, Buna-N, cable: ETFE or
polyurethane.
Accuracy: ±0.25% full scale (includes linearity, hysteresis, and repeatability).
Temperature Limit: PBLT2: 0 to 200°F (-18 to 93°C), PBLTX: 0 to 176°F (-
18 to 80°C).
Compensated Temperature Range: PBLT2: 0 to 180°F (-18 to 82°C),
PBLTX: 0 to 176°F (-18 to 80°C).
Thermal Effect: ±0.02% FS/°F.
Pressure Limit: 2X full scale.
Power Requirement: PBLT2: 13 to 30 VDC, PBLTX: 10 to 28 VDC.
Output Signal: 4 to 20 mA DC, two wire.
Response Time: 50 msec.
Loop Resistance: 900 ohms.
Electrical Connection: Wire pigtail.
Mounting Orientation: Suspended in tank below level being measured.
Weight: 4.3 lb (2.0 kg).
Electrical Protection: PBLT2: Lightning and surge protection, PBLTX:
none.
Agency Approvals: PBLT2: None, PBLTX: CE, UL intrinsically safe for
Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III,
Div. 1. (According to control drawing 01-700797-00). |