Home Product Information Free Literature International Distribution What's New About Us Contact Us
New Quick Search Order Form
Dwyer Series
475

Mk III Handheld Digital Manometer
Ranges from 1 in w.c. to 150 psid, ±0.5% Accuracy

SPECIFICATIONS
Service: Air and compatible combustible gases.
Wetted Materials: Consult factory.
Accuracy: ±0.5% F.S., 60 to 78°F (15.6 to 25.6°C); ±1.5% F.S. from 32 to 60°F and 78 to 104°F (0 to 15.6°C and 25.6 to 40°C).
Pressure Hysteresis: ±0.1% of full scale.
Pressure Limits: See chart on "Ordering" page.
Temperature Limits: 0 to 140°F (-17.8 to 60°C).
Compensated Temperature Limits: 32 to 104°F (-0 to 40°C).
Storage Temperature Limits: -4 to 176°F (-20 to 80°C).
Display: 0.42" (10.6 mm) 4-digit LCD.
Resolution: See chart on "Ordering" page.
Power Requirements: 9 volt alkaline battery. Battery not connected.
Weight: 10.8 oz. (306 g).
Connections: Two barbed connections for use with 1/8" (3.18 mm) or 3/16" (4.76 mm) I.D. tubing. Two compression fittings for use with 1/8" (3.18 mm) I.D. x 1/4" (6.35 mm) O.D. tubing for 475-7-FM & 475-8-FM only.
Agency Approvals: FM, CE.