666

Rangeable Differential Pressure Transmitter
Field Selectable Pressure Ranges, 10 psig Overpressure, ±1% Accuracy

SPECIFICATIONS
Service: Air and non-corrosive gases.
Wetted Materials: Brass.
Accuracy: ±1% of full scale (RSS), (includes non-linearity, hysteresis, and non-repeatability).
Temperature Limits: Operating: 0 to 150°F (-18 to 65°C), Storage: -65 to 180°F (-54 to 82°C).
Pressure Limits: 10 psig (0.7 kg/cm²).
Compensated Temperature Range: 40 to 150°F (5 to 65°C).
Thermal Effects: 0.033% FS/°F (0.06% FS/°C) includes zero and span.
Power Requirements: 9-30 VDC.
Output Signal: 4 to 20 mA, 2-wire.
Response Time: <60 msec.
Loop Resistance: 0-500 ohms.
Electrical Connection: Screw terminal strip with PG-9 cable strain relief.
Pressure Connection: 3/16" O.D. barbed brass pressure fitting for 1/4" I.D. tubing.
Housing: ABS plastic case, NEMA 4 (IP65).
Mounting: 2 mounting tabs with #8 holes.
Weight: 16.4 oz (465 g).
Display: 3-1/2 digit LCD.
Agency Approval: CE.