Home Product Information Free Literature International Distribution What's New About Us Contact Us
New Quick Search Order Form
Series
2800

Current to Pressure Transducer
Vibration Resistant, NEMA 4X Enclosure

SPECIFICATIONS
Service: Oil free, clean dry air filtered to 40 microns.
Input Signal:
4-20 mA.
Air Supply: Minimum: 5 psig (0.3 bar) above maximum output; Maximum: 100 psig (6.9 bar).
Output: 3 to 15 psig (0.2 to 1.0 bar), 6 to 30 psig (0.4 to 2.1 bar).
Accuracy: ±0.1% of span.
Hysteresis: ±0.1% of span.
Repeatability: ±0.1% of span.
Deadband: 0.02% of span.
Power Requirement: Loop powered.
Temperature Limits: Operating: -40 to 160°F (-40 to 71°C); Storage: -40 to 200°F (-40 to 93°C).
Pressure Connections: 1/4" female NPT.
Electrical Connection: 1/2" female NPT.
Air Consumption:
0.025 scfm (0.01 l/s) at midrange typical.
Output Capacity: 4.5 scfm (2.1 l/s) at 25 psig (1.7 bar) supply; 12.0 scfm (5.7 l/s) at 100 psig (6.9 bar) supply.
Enclosure: Chromate-treated aluminum with epoxy paint.
Enclosure Rating: NEMA 4X (IP65) and intrinsically safe.
Weight: 0.8 lb (0.37 kg).
Agency Approvals: CE, CSA, FM.

FM Intrinsically Safe Ratings:
Class I, II, III, Division 1, Groups C, D, E, F and G; Class I, Zone 0, Group IIB; Class I, II and III, Division 2, Groups A, B, C, D, F and G.

CSA Intrinsically Safe Ratings:
Class I, Division 2, Groups A, B, C and D; Class II, Division 2, Groups F and G; Class III.