Skip to Content
Language
English
  • Spanish
  • Chinese
Dwyer Toggle Nav

+44 (0) 1494 461707
sales@dwyer-inst.co.uk

  • Markets
    • Building Automation
    • Powder & Bulk
    • Water & Wastewater
    • Valve Automation
    • HVAC
  • Resources
    • Free Literature
    • Mobile Apps
    • Glossary of Terms
    • Unit Converters
    • Technical Questions
    • Industry Articles
    • Application Guides
    • Product Documents
  • News
    • New Products
    • News Releases
    • Awards
    • Trade Fairs
    • Serving Our Community
  • About Us
    • Dwyer Mission
    • Global Contacts
    • Manufacturing Excellence
    • History Of Dwyer
    • Innovation
    • Testimonials
    • Hours of Business
    • Email Us
    • Website Feedback
  • Catalog
    • Digital Catalog
    • Catalog Request
  • Videos
  • Blog
  • Careers
    • Internships
Menu
  • Products
    • Calibration Services
    • Pressure
    • Air Quality
    • Air Velocity
    • Flow
    • Level
    • Temperature
    • Test Equipment
    • Valves
    • Miscellaneous
    • Hazardous Rated
    • Discontinued Products
Account
Settings
Language
English
  • Spanish
  • Chinese
Search
Advanced Search
  • Login Or Register
Cart 0
  • Home
  • /
  • Products
  • /
  • Miscellaneous
  • /
  • Accessories
  • Products
    Calibration Services
    1. DEMO 1
    2. DEMO 2
    3. DEMO 3
    4. DEMO 4
    5. DEMO 5
    Pressure
    1. DEMO 1
    2. DEMO 2
    3. DEMO 3
    4. DEMO 4
    5. DEMO 5
    Air Quality
    1. DEMO 1
    2. DEMO 2
    3. DEMO 3
    4. DEMO 4
    5. DEMO 5
    Air Velocity
    1. DEMO 1
    2. DEMO 2
    3. DEMO 3
    4. DEMO 4
    5. DEMO 5
    Flow
    1. DEMO 1
    2. DEMO 2
    3. DEMO 3
    4. DEMO 4
    5. DEMO 5
    Level
    1. DEMO 1
    2. DEMO 2
    3. DEMO 3
    4. DEMO 4
    5. DEMO 5
    Temperature
    1. DEMO 1
    2. DEMO 2
    3. DEMO 3
    4. DEMO 4
    5. DEMO 5
    Test Equipment
    1. DEMO 1
    2. DEMO 2
    3. DEMO 3
    4. DEMO 4
    5. DEMO 5
    Valves
    1. DEMO 1
    2. DEMO 2
    3. DEMO 3
    4. DEMO 4
    5. DEMO 5
    Miscellaneous
    1. DEMO 1
    2. DEMO 2
    3. DEMO 3
    4. DEMO 4
    5. DEMO 5
    Hazardous Rated
    1. DEMO 1
    2. DEMO 2
    3. DEMO 3
    4. DEMO 4
    5. DEMO 5
    Filters, Regulators and Lubricators
    For Pneumatic systems, liquid, nylon, and particle filters, air pressure, and air filter regulators are available. Replaceable filter elements remove particles and droplets as small as .01 micron with 93-95% efficiency. Applications are for substantial flow capacity.
    View More
    Three-Way Valve
    Three Way valves are for pneumatic tubing systems. Dwyer's instruments are able to hook 3 instruments together, tests various gages and transmitters. Constructed of solid gray PVC, has Buna-N seals, and a rotating flag handle. The handle has 180° rotation and lies directly over the open port.
    View More
    Gage Guards/Pressure Snubbers
    Pressure snubbers protect pressure instruments from pressure surges. Gauge guards provide a protective barrier between the process fluid and the instrument. The adjustable pressure snubbers are fine thread adjustable valves that allow you to fine tune harmful harmonic vibration from the fluid systems.
    View More
    Pneumatic Valves
    Pneumatic valves are directly for pneumatic tubing systems.
    View More
    Pneumatic Fittings
    Pneumatic fittings are for pneumatic tubing systems.
    View More
    Fittings, Stainless Steel
    Pneumatic fittings are made of stainless steel. Dwyer's fittings are designed and manufactured to provide reliable leak-free connections in a variety of applications. The tubing material chosen must be compatible with the system's contained media, pressure and temperature, as well as with the environment in which it will be installed.
    View More
    Fittings, Nylon
    Pneumatic fittings are made of nylon. Nylon fittings are generally acceptable for use at working pressures up to 150 psi at normal room temperatures, and at very low pressures, temperatures can approach 175°F.
    View More
    Static Pressure Sensors
    Static Pressure sensors are for use with pressure gages, switches, transmitters and other controllers to pick up or sense static pressure drop across air filters and cooling coils, blower input and discharge pressures, etc.
    View More
    Valves / Connectors
    Valves and connectors are for pneumatic tubing systems. Specifically for manometers and gages. Instrument valves are for permanent installation.
    View More
    Fittings, Filters & Mufflers
    Fittings, filters, and mufflers to pneumatic tubing systems. Special line filters for gage and particulate filters. The Muffler Accessory can be easily field installed to any diaphragm valve with an exhaust. Particulate filters are used for Dwyer Flowmeters to keep the air clean.
    View More
    Mounting Options
    Mounting flanges and brackets for pressure gages. Various mounting options for Dwyer products. Enclosures protects instruments in all applications.
    View More
    Carrying Cases
    Portable case accessories for test equipment. Steel cases are substantially constructed and finished in gray hammerloid. Molded plastic cases are gray, high density polyethylene.
    View More
    Psychrometer & Slide Charts
    Sling psychrometers and calculator slide charts. Psychrometers are used for handheld, non-electric humidity metering. Air Velocity Calculator Slide Charts make spot checking with Dwyer Pitot Tubes quick and easy.
    View More
    Air Filter Kits
    Accessory kits are for pressure instruments to measure filter pressure drop. They are used with differential pressure gages or switches to measure the resistance of air flow through filters.
    View More
    Gage Fluids
    Replacement fluids for fluid filled manometers. The different fluids are red gage fluid, blue gage fluid, and fluorescein green color concentrate. Dwyer's fluids are furnished in unbreakable plastic dispenser type bottles.
    View More
    Technical Reference Books
    Technical references for HVAC, pumps, boilers, electrical codes, instrumentation, chemical resistance, indoor air quality, facilities, plant management, and more.
    View More
    Regulator Kit
    Flow regulator kits for RM and VF flowmeters. Recommended for use where inlet air pressure fluctuates widely and constant flow is required. For higher flow rates, factory needs to be consulted.
    View More
    Tubing
    Tubing for pneumatic systems. The different types include Clear PVC tubing, rubber tubing, aluminum tubing, flexible double column tubing, Norprene tubing, flexible colored vinyl tubing, and black plenum fire retardant polyethlene tubing.
    View More
    Siphons
    Siphons protect pressure instruments in high temperature applications. Water held in the 180° coil prevents steam from contacting the instrument. Ideal for use with pressure gages and instrumentation where the process media temperature exceeds the rating of the instrument.
    View More
    Thermocouple Wire
    General purpose thermocouple wire is offered in the two most common types of thermocouples used, type J and type K. Both FEP insulation and Fiberglass insulation options are available in multiple pre-spooled lengths meeting any application needs.
    View More
    Enclosures
    View More
    • Most Popular
    • Questions

    Most Popular

    Static Pressure Tips & Accessories
    Gage Tubing Accessories
    Mounting Options
    Fittings/Filters/Mufflers

    Questions

    Question
    Will a Dwyer pressure switch be damaged if the pressure exceeding the maximum set-point is applied to the switch?
    Answer
    No. Not unless the maximum pressure rating of the switch is exceeded.
    Related
    Series A-3000
    Series PDPS
    Series 3000MR/3000MRS
    Series ADPS/EDPS
    Series 1900
    Series 1800
    Question
    How do I hook up my Magnehelic® gage for an air velocity application with a pitot tube?
    Answer
    In our Application Guides on flow products, we explain very well how to take air velocity readings. The total pressure connection on the pitot tube is connected to one of the high pressure ports on the gage. The other high pressure port is plugged. The static pressure connection on the pitot tube is connected to one of the low pressure ports on the gage. The other low pressure port is plugged.
    Related
    Static Pressure Tips & Accessories
    Series 2000
    Series 160
    Question
    How often should I replace the filter on my 1205A-0 handheld CO analyzer?
    Answer
    This filter should be replaced if it begins to appear wet or dirty and can be replaced with Model F195 Air Filter.
    Related
    Model F195
    Question
    Trying to measure differential pressure between OSA and indoors. Using transmitters with a range of +25pa to -25pa. Monitoring pressure variations occur from basically 0pa to 20pa over a short period of time (15 to 30 sec) Building is basically closed during testing, suspect OSA fluctuating due to winds? eddy currents etc. Any ideas, Building under positive pressure is critical for safety reasons Any ideas?
    Answer
    Whenever you are using outside air for a static pressure reference, fluctuations in outside conditions can cause erratic differential pressure readings. By using one of our outdoor static reference probes, you can diminish the influence of outdoor weather on your reading.
    Related
    Static Pressure Tips & Accessories
    Question
    What might be the cause for Magnehelic® gages filling approximately 1/3 full of water, with lots of liquid droplets on the glass. Both are outside mounted on the side of an air stripping tower. One is a differential pressure gage that measures the pressure drop across a pitot tube. The other just measures the back pressure in the stripper. What can be done to fix the malfunction?
    Answer
    It looks like you’re getting some condensation in the Magnehelic®, which is causing it to collect on the bottom of the face. Since the Magnehelic® is not encapsulated, it is not recommended to be used in applications where moisture can form. One option to fix the problem is installing a liquid filter (like an F222) to filter out that moisture. Another option is to install a Capsuhelic (Series 4000), which is made to handle both air and liquid.
    Related
    Series 4000
    Series 2000
    Model F222/Model F451
    Divisions
    Markets
    • Building Automation
    • Powder & Bulk
    • Water & Wastewater
    • Valve Automation
    • HVAC
    Our Company
    • History Of Dwyer
    • What's New
    • Digital Catalog
    • Free Literature
    • Careers
    • Mobile Apps
    • Contact Us
    • Hours Of Business
    Support
    • FAQ
    • Agency Approval Certificates
    • Catalog Pages
    • Instruction Manuals
    • Safety Data Sheets
    • Calibration & Certificate Services
    • Website Feedback
    • Website Survey
    • International Distributor Login
    • Policies, Terms, ETC.
    • Global Trade Compliance
    • Environmental Policies
    • Sales Tax
    • Map Policy
    • Trademark Policy
    • Trademark Acknowledgements
    T: +44 (0) 1494 461707 E: sales@dwyer-inst.co.uk
    Copyright © Dwyer Instruments LTD. All Rights Reserved.